Receiver principle | superheterodyne with digital demodulation |
Receiving channels | 2 |
Receiver compatibility | digital modulation: Digital 9000 LR mode wideband FM: HiDyn Plus, HDX |
Frequency ranges | 470 to 654 MHz |
Switching bandwidth | 184 MHz |
Step width | ≥ 5 kHz |
Reeption diversity | „LR mode“: <−90 dBm „FM mode“: <−94 dBm @52 dB Audio SNR |
Antenna inputs | 2 SMA sockets (50 Ω) |
Antenna type | 2 UHF wideband antennas |
Adjacent channel selection | typ. 70 dB (channel spacing ≥ 400 kHz) |
Audio frequency response | 20 Hz to 20 kHz (+/−1,5 dB) |
Dynamic range | > 108 dB(A) |
THD | „LR mode“: < 0,03 % (at 1 kHz) „FM mode“: < 0,5 % (at 1 kHz) |
Latency | „LR mode“: 3,0 ms (AES3) „FM mode“: 1,5 ms (AES3) |
Audio outputs | 5-pin mini-XLR (male), balanced |
MAIN 1/2 digital: analog: | 0 dBFs, AES3, 48 kHz, 24 bit -22 dBu bis +8 dBu (adjustable) |
(Top) AUX 1/2 analog: | -22 dBu bis +8 dBu (adjustable) |
Dimensions (H x B x D) | approx. 107 x 90 x 26 mm (without antennas) |
Weight | approx. 340 g |
Configuration interface | micro USB socket, type B |
Multi-pin interface | 60-pin connector for GA 6042 adapters |
Power consumption | typ. 3 W at 12 V (7 to 18 V) |
Input voltage | 4-pin DC IN socket, typ. 12 V (7 to 18 V) |
Headphone output | 3,5 mm jack connector 2 x 25 mW at 32 Ω, |
Dimensions (H x B x D) | approx. 135 x 90 x 26 mm |
Audio outputs | 5 pin mini XLR (male), balanced |
MAIN 1/2 digital: analog: | 0 dBFs, AES3, 48 kHz, 24 bit -22 dBu to +8 dBu (adjustable) |
(Top) AUX 1/2 analog: | -22 dBu to +8 dBu (adjustable) |
Compatible accupack | Sennheiser BA 61 |
Operating time | > 4 h (with 2 x accupack BA 61) |
Dimensions (H x B x D) | approx. 135 x 90 x 44 mm |
D-sub adapter | GA 6042-15 | GA 6042-25 |
Camera interface | D-Sub-15 (Male) (Sony) | D-Sub-25 (Male) (UniSlot/SuperSlot™) |
Dimensions (H x B x D | approx. 135 x 90 x 26 mm |
Ambient temperature | -10 °C to +55 °C |
Relative Air humity | max. 90 % at 40 °C (non condensing) |
Protection against dripping and light splashing of liquids | The product must not be exposed to dripping and splashing (IP2X) |
Ambient temperature | -25 °C to +70 °C |
Relative air humidity | max. 90 % at 40 °C (non condensing)) |
Protection against dripping and light splashing of liquids | The product must not be exposed to dripping and splashing (IP2X) |
Shock resistance | as per IEC 68 or EN 60068, T2‑27 |