EK 6042 : SPECIFICATIONS : Specifications
Specifications
RF characteristics 
►  
Receiver principle
superheterodyne with digital demodulation
Receiving channels
2
Receiver compatibility
digital modulation: Digital 9000 LR mode
wideband FM: HiDyn Plus, HDX
Frequency ranges
470 to 654 MHz
Switching bandwidth
184 MHz
Step width
≥ 5 kHz
Reeption diversity
„LR mode“: <−90 dBm
„FM mode“: <−94 dBm @52 dB Audio SNR
Antenna inputs
2 SMA sockets (50 Ω)
Antenna type
2 UHF wideband antennas
Adjacent channel selection
typ. 70 dB (channel spacing ≥ 400 kHz)
 
Audio characteristics 
►  
Audio frequency response
20 Hz to 20 kHz (+/−1,5 dB)
Dynamic range
> 108 dB(A)
THD
„LR mode“: < 0,03  % (at 1 kHz)
„FM mode“: < 0,5 % (at 1 kHz)
Latency
„LR mode“: 3,0 ms (AES3)
„FM mode“: 1,5 ms (AES3)
Audio outputs
5-pin mini-XLR (male), balanced
MAIN 1/2 digital:
analog:
0 dBFs, AES3, 48 kHz, 24 bit
-22 dBu bis +8 dBu (adjustable)
(Top) AUX 1/2 analog:
-22 dBu bis +8 dBu (adjustable)
 
Other characteristics 
►  
Dimensions (H x B x D)
approx. 107 x 90 x 26 mm
(without antennas)
Weight
approx. 340 g
Configuration interface
micro USB socket, type B
Multi-pin interface
60-pin connector for GA 6042 adapters
 
Operation with GA 6042 BP backpanel adapter 
►  
Power consumption
typ. 3 W at 12 V (7 to 18 V)
Input voltage
4-pin DC IN socket,
typ. 12 V (7 to 18 V)
Headphone output
3,5 mm jack connector
2 x 25 mW at 32 Ω,
Dimensions (H x B x D)
approx. 135 x 90 x 26 mm
Audio outputs
5 pin mini XLR (male), balanced
MAIN 1/2 digital:
analog:
0 dBFs, AES3, 48 kHz, 24 bit
-22 dBu to +8 dBu (adjustable)
(Top) AUX 1/2 analog:
-22 dBu to +8 dBu (adjustable)
 
Operation with GA 6042 BA accupack adapter 
(requires the GA 6042 BA for operation)
►  
Compatible accupack
Sennheiser BA 61
Operating time
> 4 h
(with 2 x accupack BA 61)
Dimensions (H x B x D)
approx. 135 x 90 x 44 mm
 
Operation with D-sub adapters 
►  
D-sub adapter
GA 6042-15
GA 6042-25
Camera interface
D-Sub-15 (Male)
(Sony)
D-Sub-25 (Male)
(UniSlot/SuperSlot™)
Dimensions (H x B x D
approx. 135 x 90 x 26 mm
 
Operating conditions 
►  
Ambient temperature
-10 °C to +55 °C
Relative Air humity
max. 90 % at 40 °C
(non condensing)
Protection against dripping and light splashing of liquids
The product must not be exposed to dripping and splashing (IP2X)
 
Storage and transport conditions 
►  
Ambient temperature
-25 °C to +70 °C
Relative air humidity
max. 90 % at 40 °C
(non condensing))
Protection against dripping and light splashing of liquids
The product must not be exposed to dripping and splashing (IP2X)
Shock resistance
as per IEC 68 or EN 60068, T2‑27