MAINTENANCE AND TROUBLESHOOTING : Factory reset
Factory reset
Resetting the ConnectStation via Admin Interface
To reset the ConnectStation to factory settings:
*Connect your computer to LAN3 of the ConnectStation.
*Open a browser and navigate to 192.168.0.10.
*Login with your user credentials.
*In the Update & Reset tab click on Perform reset now.
The ConnectStation will be reset to factory settings.
 
Resetting the ConnectStation via USB keyboard
To reset the ConnectStation via USB keyboard:
*Connect the access point to the ConnectStation.
*Power up both the ConnectStation and the access point.
*Wait until the system is ready (2-3 min).
*Connect a USB keyboard to one of the USB sockets of the ConnectStation.
*Type reset and press Enter.
*The ConnectStation and the access point will be reset to factory settings.
*Log into the admin interface with the default login details:
Username: admin
Password: sennheiser
*If the admin interface shows that the access point is not getting connected, a hard reset of the access point has to be performed. See below: "Resetting the access point").
 
Resetting the access point
To reset the access point Ruckus ZoneFlex 7372 to factory settings:
*Disconnect the access point from its power supply.
*Press and hold the RST (reset) button of the access point.
*Insert the power supply into the access point while holding the RST button.
*Hold the RST button for approximately 15 seconds.
The access point will be reset to factory settings.